HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 March 2012 Data Sheet
Table 16-71 HP_DeviceIndication: SAS HBA status OK
Property name
Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Controller firmware version string
HWLogicalLocation Controller Location string
For example, Slot 3
HWManufacturer
Controller Manufacturer string
HWSerialNumber
Controller Serial Number
HP_DeviceIndication
DeviceModel
Controller Model string
1-2-2 SAS HBA in Error state
Table 16-72 HP_DeviceIndication: SAS HBA in Error state
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity Severity
• 5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A SAS/SATA HBA status has changed to Error.
AlertingManagedElement
WBEM Path of controller
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
2
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
Replace the HBA.
SystemName
Name of the computer system generating the indication