HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 September 2013 Datasheets

Table Of Contents
HP Insight Management WBEM System Temperature Sensor Provider 3
Property Name
Property Implementation
Temperature Sensor Temp 1
Description
“Temperature Sensor <sensorID> detects for
NumericSensorType.StatusDescription”
Where: <sensorID>” is the name displayed by the MP or iLO
represents the number of the temperature sensor instance,
NumericSensorType represents the value of
NumericSensorTypeand StatusDescription represents the value
of
StatusDescriptions[0].
ElementName
“Temperature Sensor <sensorID>”
Where: <sensorID> is the name displayed by the MP or iLO.
For example:
Temperature Sensor Temp 1
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) if temperature reported by the sensor is within normal operating
range or
if temperature reported by the sensor has exceeded its non-critical
threshold and has set fans to full speed;
6 (Error) if temperature reported by the sensor has exceeded its
threshold and the system is gracefully shutting down.
StatusDescriptions[0]
Temperature reported by the sensor is within normal
operating rangeif temperature reported by the sensor is within
normal operating range;
Temperature reported by the sensor has exceeded its
non-critical threshold and the fans have been set to
full speed
if temperature reported by the sensor has exceeded its
threshold and has set fans to full speed;
Temperature reported by the sensor has exceeded its
threshold and the system is gracefully shutting down
if
OperationalStatus is 6 (Error)