HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 September 2013 Datasheets

Table Of Contents
HP Insight Management WBEM CPU Provider Overview 10
Property Name
Property Implementation
StatusDescriptions
StatusDescriptions[0]
text per
OperationalStatus[0]
:
Unknown.
OK
Predictive Failure
Error
Stopped
HealthState
0 (Unknown), when OperationalStatus[0]=0 (Unknown)
5 (OK), when OperationalStatus[0]=2 (OK)
15 (Minor Failure), when OperationalStatus[0]=10 (Stopped)
20 (Major Failure), when OperationalStatus[0]=5 (Predictive Failure)
25 (Critical Failure), when OperationalStatus[0]=6 (Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledState
2 (Enabled)
RequestedState
12 (Not Applicable)
EnabledDefault
2 (Enabled)
CIM_ProcessorCore
InstanceID
HPQ:SMX_ProcessorCore Proc:<p> Core:<c>
Where: <p> is the processor number and <c> is the core number.
CoreEnabledState
2
(Core Enabled)