HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 September 2013 Datasheets

Table Of Contents
HP Insight Management Power Supply Provider Overview 28
Property Name
Property Implementation
supply was removed intentionally.
HP_AlertIndication
Summary
Power supply removed
EventCategory
16 (System Power)
ProbableCause
1 (Other)
ProbableCauseDescription
Power Supply Removed
1-3-4 HP_DeviceIndication: Power Supply Inserted
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description
A power supply has been inserted. PowerSupplyCaption
Where: PowerSupplyCaption is the
SMX_PowerSupply.Caption for the power supply that has been
inserted.
AlertingManagedElement
WBEM Path of SMX_PowerSupply instance representing the inserted
power supply.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
2
ProviderName
HP Power