HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 September 2013 Datasheets

Table Of Contents
HP Insight Management Power Supply Provider Overview 18
Property Name
Property Implementation
For example:
PowerSupplySlot=2
CIM_PhysicalElement
CreationClassName
SMX_PowerSupplySlot
Tag
Unique identifier for this power supply slot.
CIM_PhysicalPackage
ConnectorLayout
6 (Slot)
Number
<n>
Where: <n> represents the number of the power supply slot.
1-2-15 SMX_SystemPowerSupplySlot Class
The SMX_SystemPowerSupplySlot class extends the CIM_Container class and association of the
HP_ComputerSystemChassis instance with HP_PowerSupplySlot.
The following table lists the properties implemented.
Property Name
Property Implementation
GroupComponent
References HP_ComputerSystemChassis
PartComponent
References HP_PowerSupplySlot
1-2-16 SMX_PowerSupplyInSlot Class
The SMX_PowerSupplyInSlot class extends the CIM_ElementInConnector class and associates the
HP_PowerSupplySlot instance with HP_PowerSupplyModuleinstances.
The following table lists the properties implemented.
Property Name
Property Implementation
Antecedent
References HP_PowerSupplySlot