Programming instructions

66 Chapter 3
Troubleshooting
Selftest Failures
FLT 7846 SYS BD mem err overflow
Multiple memory errors detected.
FLT 7848 SYS BD addr not mapped
Memory address outside configured
memory space.
FLT 785
s
DIMM MBE in DIMM
s
Destructive memory test detected an
uncorrectable memory error in DIMM s.
FLT 786
s
DIMM SBE&MBE DIMM
s
Destructive memory test detected both an
uncorrectable and a correctable memory
error in DIMM s.
FLT 787
s
DIMM mem err DIMM
s
Destructive memory test detected a
pattern compare error in DIMM s.
FLT 788
s
DIMM SBE in DIMM
s
Destructive memory test detected a
correctable memory error in DIMM s.
FLT 7890 DIMM MBE overwrt SBE
Firmware replaced a correctable memory
error entry in the PDT with an
uncorrectable memory error entry at the
same address.
FLT 7891 DIMM dup entry in PDT
The PDT already contains an entry at
that address.
FLT 7892 SYS BD PDT write error
Error adding the entry to the PDT.
FLT 7893 SYS BD PDT is full
The PDT is full--cannot add new entry.
FLT 7900 SYS BD no DMT entry
Internal error--cannot find DIMM entry.
FLT 7901 SYS BD no rank entry
Internal error--cannot find rank entry.
FLT 7902 SYS BD bad refrsh intvl
Computed refresh interval is invalid.
FLT 7903 SYS BD mem intrlv fail
Cannot generate memory interleave.
FLT 7904 SYS BD mem reloc failed
Cannot interleave with relocated range
(3.75GB - 4.0GB).
FLT 7905 SYS BD mem intrlv error
Undefined memory interleave failure.
FLT 79FF SYS BD mem firmware err
Internal error--never expected this to
happen.
WRN 80F3 SYS BD err rd IODC byte
Cannot read IODC from ROM or card.
WRN 80F4 EXT IO boot read error
Cannot load IODC entry_init for boot
device.
WRN 80F5 EXT IO boot exec error
Error initializing boot device.
WRN 80F6 EXT IO boot read error
Cannot load IODC entry_io for boot
device.
Table 3-2. Chassis Codes for the B2000 Workstation
Ostat Code FRU Message
Description