Programming instructions
Chapter 3 65
Troubleshooting
Selftest Failures
FLT 7611 DIMM ECC single data
Memory ECC test failed to detect
single-bit data error.
FLT 7612 DIMM ECC single ECC
Memory ECC test failed to detect
single-bit ECC error.
FLT 7613 DIMM ECC multipl data
Memory ECC test failed to detect
multiple-bit data error.
FLT 7614 DIMM ECC multpl signl
Memory ECC test failed to signal
multiple-bit error.
FLT 7800 SYS BD mem err summary
Printing memory error summary word to
RS-232.
FLT 7801 SYS BD bus ctrl par err
System bus (Runway) control parity error
detected.
FLT 7802 SYS BD bus addr par err
System bus (Runway) address parity error
detected.
FLT 7803 SYS BD bus data par err
System bus (Runway) data parity error
detected.
FLT 7804 SYS BD mem out of range
Memory access outside configured
memory space.
FLT 7805 SYS BD bus broadcst err
System bus (Runway) broadcast error
detected.
FLT 7806 SYS BD mem addr par err
Memory bus address parity error
detected.
FLT 7807 SYS BD mem ctlr stat wd
Printing memory controller status word to
RS-232.
FLT 781
s
SYS BD DIMM
s
uncor err
Uncorrectable ECC error detected in
DIMM s.
FLT 782
s
SYS BD DIMM
s
corr err
Correctable ECC error detected in DIMM
s.
FLT 7840 SYS BD unexpected HPMC
Unexpected HPMC detected.
FLT 7841 SYS BD mem status invld
Memory error status word is invalid.
FLT 7842 SYS BD mem summ invalid
Memory summary word is invalid.
FLT 7843 SYS BD fwd prog invalid
Memory forward progress word is invalid.
FLT 7844 SYS BD mem HPMC summ wd
Printing memory error summary word to
RS-232.
FLT 7845 SYS BD mem ctlr stat wd
Printing memory controller status word to
RS-232.
Table 3-2. Chassis Codes for the B2000 Workstation
Ostat Code FRU Message
Description