Programming instructions
Chapter 3 63
Troubleshooting
Selftest Failures
FLT 7207 DIMM DIMM table full
The DIMM table is full--cannot add new
type.
FLT 7208 DIMM no DIMMs found
SPD didn’t find any memory DIMMs.
INI 721
s
DIMM is DIMM
s
inst?
SPD is checking memory slot s.
INI 722
s
DIMM ???? DIMM in
s
SPD found a DIMM in slot s, but can’t
determine its size. DIMM will not be used.
INI 723
s
DIMM 128M DIMM in
s
SPD found a 128MB DIMM in slot s.
INI 724
s
DIMM 256M DIMM in
s
SPD found a 256MB DIMM in slot s.
INI 725
s
DIMM 512M DIMM in
s
SPD found a 512MB DIMM in slot s.
FLT 72A
s
DIMM DIMM
s
checksum
DIMM in slot s failed SPD checksum and
will not be used.
FLT 72C
s
DIMM DIMM
s
mismatch
DIMM in slot s didn’t match the other in
pair. (J7000 only--DIMMs must be in
matched pairs.)
FLT 72D
s
DIMM DIMM
s
load err
Memory DIMMs are not in the proper
order. As a result, the system cannot
access DIMM s and has deallocated it.
INI 7300 SYS BD mem config start
Starting main memory configuration.
TST 7301 SYS BD check mem config
Checking for memory configuration
change since last boot.
WRN 7302 SYS BD mem confg changd
Memory physical configuration changed
since last boot.
INI 7303 SYS BD use confg change
Memory physical configuration didn’t use
saved configuration change. Use stored
configuration data.
INI 7304 SYS BD build mem intrlv
Building memory configuration with all
DIMMs interleaved.
INI 7305 SYS BD save mem config
Saving memory configuration information
in non-volatile memory.
WRN 7306 SYS BD use alt mem conf
Memory will be configured from fixed
values, instead of detected DIMMs.
INI 7307 SYS BD interleve memory
Generating the memory interleave.
FLT 7308 SYS BD PDT is disabled
Firmware detected bad memory pages,
but the Page Deallocation Table is
disabled.
Table 3-2. Chassis Codes for the B2000 Workstation
Ostat Code FRU Message