Programming instructions

62 Chapter 3
Troubleshooting
Selftest Failures
TST 7020 SYS BD search for IMM
Try to find a single memory bank to use
for the initial memory module.
TST 703
s
DIMM DIMM
s
IMM vrfy
DIMM s was the initial memory module
last boot. Verify it still works.
FLT 704
s
DIMM DIMM
s
IMM fail
DIMM s failed the initial memory module
test.
TST 705
s
DIMM DIMM
s IMM test
Test DIMM in slot s as the initial memory
module.
INI 706
s
DIMM DIMM
s
is IMM
DIMM s chosen as initial memory module.
INI 70F0 DIMM DIMM scan done
Memory DIMM scan complete.
TST 7100 SYS BD mem register tst
Start testing registers in memory
controller.
WRN 7101 SYS BD skip mem reg tst
Bypass the memory controller register
test.
FLT 7102 SYS BD mem addr reg tst
Firmware detected an error in the
memory controller address registers.
FLT 7103 SYS BD mem mbat reg tst
Firmware detected an error in the
memory controller bank registers.
FLT 7104 SYS BD mem reg tst fail
Firmware detected an error in the
memory controller memory registers.
FLT 7105 SYS BD mem err reg test
Firmware detected an error in the
memory controller error registers.
FLT 7106 SYS BD mem err clr fail
Firmware was unable to clear the error
registers after testing.
INI 7200 DIMM strt DIMM detect
Start the Serial Presence Detection (SPD)
to search for memory DIMMs.
INI 7201 DIMM DIMM detect
x
%
SPD is x% finished.
WRN 7202 SYS BD skip DIMM detect
Bypass Serial Presence Detection.
FLT 7203 DIMM unsupp DIMM type
SPD found an unsupported DIMM type.
FLT 7204 DIMM SPD fatal error
SPD detected an unexpected, fatal error.
INI 7205 DIMM add HP DIMM type
New HP manufactured DIMM type added
to tables.
INI 7206 DIMM non-HP DIMM type
New non-HP DIMM type added to tables
(use at own risk).
Table 3-2. Chassis Codes for the B2000 Workstation
Ostat Code FRU Message
Description