Programming instructions
Chapter 3 57
Troubleshooting
Selftest Failures
FLT 1
n
BA SYS BD monarch CPU
fail
The monarch CPU failed.
FLT 1
n
BB SYS BD bad CPU
n
number
The CPU identifier was out of range.
FLT 1
n
BF SYS BD CPU
n
halt boot
Bootstrap failure--machine halted.
INI 1
n
CA SYS BD CPUn sys bus arb
Monarch CPU is initializing the system
bus arbitration.
WRN 1
n
CD SYS BD CPU
n
deconfig
CPU n deconfigured itself.
WRN 1
n
CE SYS BD CPU
n
extinguish
PDC_PROC halted CPU n.
FLT 1
n
CF SYS BD slave
n
failed
Slave CPU n failed self-test.
WRN 1
m
D
s
SYS BD slaves deconfig
Monarch CPU m deconfigured slave CPU
s.
WRN 1
n
EF SYS BD CPU
n
slftst warn
CPU n detected a non-fatal error during
its self-tests.
WRN 1
m
F
s
SYS BD mon
m
stop slave
s
Monarch CPU m halted slave CPU s.
INI 1
n
FC SYS BD CPUn sync’ing
CPU n is synchronizing with the rest of
the system.
INI 1
n
FD SYS BD CPU
n
stat wd tst
CPU n is testing the system status word.
FLT 1
n
FF SYS BD monarch
n
selftst
Monarch CPU n failed self-test.
TST 2
n
20 SYS BD CPU
n
icache RAM
CPU n is starting its instruction cache
RAM self-test.
FLT 2
n
25 SYS BD CPU
n
ic ld d err
CPU n detected a data error during data
cache load.
FLT 2
n
26 SYS BD CPU
n
ic ld t err
CPU n detected a tag error during data
cache load.
TST 2
n
30 SYS BD CPU
n
icache tag
CPU n is starting its instruction cache tag
self-test.
TST 2
n
40 SYS BD CPU
n
icache par
CPU n is starting its instruction cache
parity detection self-test.
TST 2
n
50 SYS BD CPU
n
dc stor que
CPU n is starting its data cache store
queue self-test.
FLT 2
n
51 SYS BD CPU
n
dc st q err
CPU n detected an error during its data
cache store queue self-test.
TST 2
n
70 SYS BD CPU
n
dcache RAM
CPU n is starting its data cache RAM
self-test.
TST 2
n
80 SYS BD CPU
n
dcache tag
CPU n is starting its data cache tag
self-test.
Table 3-2. Chassis Codes for the B2000 Workstation
Ostat Code FRU Message
Description