User's Manual
Virtual Connect networks 97
Task Action
Accept selected ports and return
to the Port Monitoring screen
Click OK.
Clear newly selected ports
without saving and return to the
Port Monitoring screen
Click Cancel.
Reset the filter criteria to include
all items in each filter
Click Reset Filters.
Only display selected ports
Select the Only display selected ports check box.
Ethernet Networks (Advanced Settings)
Use this screen to perform the following tasks:
• Set Server VLAN Tagging Support (on page 97).
• Set VLAN Capacity (on page 98).
• Use the Multiple Networks Link Speed Settings (on page 98) to set a custom value for preferred link
connection speed or maximum link connection speed.
• Enable or disable MAC Cache Failover (on page 99).
• Modify the refresh interval for MAC Cache Failover (on page 99).
• Enable or disable Network Loop Protection (on page 100) for all VC-Enet modules in the domain.
• Reset Network Loop Protection for all server ports in a loop-detected error state.
• Enable or disable Pause Flood Protection (on page 101) for all VC-Enet modules in the domain.
• Reset Pause Flood Protection for all server ports in a pause flood protected error state.
• Enable and configure Throughput Statistics ("Configuring Throughput Statistics" on page 102) for all
ports of each VC-Enet module, including Flex-10 subports.
• Configure domain wide LACP timer ("LACP timer configuration" on page 102).
Server VLAN tagging support
VLAN tunneling support
You can tunnel VLAN tags and map VLAN tags in the same domain. As of VC 3.30, tunneling and mapping
is configured at the network level, not at the domain level. Server VLAN tunneling is supported only on
networks with dedicated uplinks and cannot be used with shared uplink sets.
Server VLAN tagging support
When the 'Force server connections to use same VLAN mappings as shared uplink sets' check box is
selected, server ports connected to multiple VC Ethernet networks are forced to use the same VLAN mappings
as those used for the corresponding shared uplink sets. This action forces all server connections mapped to
multiple networks to be linked to a shared uplink set. Server administrators cannot override this selection
when creating or editing a profile. When this check box is selected, server network connections can only be
selected from a single shared uplink set.
When the 'Force server connections to use same VLAN mappings as shared uplink sets' check box is not
selected, server network connections can be selected from any VC Ethernet network and the external VLAN