User's Manual
Virtual Connect networks 96
Although you can select individual FlexNICs as monitored ports, VCM mirrors traffic on a physical port basis.
To filter the list of ports, select one or more of the boxes at the top of the screen.
The following table describes the available actions in the Select Monitored Ports screen.
Task Action
Select a port to be monitored
Select the check box corresponding to the port. When 16 ports have been
selected, no additional check boxes are displayed. You must clear a
check box to select a different port.
Remove a port from the
monitored list
Clear the check box corresponding to the port.
Filter by Interconnect Module
Filter the list by interconnect
module server port
Select All Module Ports or a single port from the Filter by Interconnect
Module ports list.
Filter the list by I/O bay
Select All Module Bays or a single I/O bay from the Filter by Interconnect
Module Module bay list. Only I/O bays with VC-Enet interconnect devices
are displayed.
Filter the list by enclosure
Select All Enclosures or a single enclosure from the Filter by Interconnect
Module enclosure list.
Filter by Profile
Filter the list by a specific profile
Select All Profiles or a single profile from the Filter by Profile profiles list.
The assigned networks are listed by each subport. If multiple networks are
assigned, mouse over the label to see a listing of all networks associated
with the subport.
Filter by Physical Server
Filter the list by server bay
Select All Bays or a single bay from the Filter by Physical Server bay list.
The list displays the actual server type installed in the bay, for example,
"Server Bay 1 HP ProLiant BL420c Gen8." If more than one enclosure is
imported into the domain, options are grouped according to the enclosure
name.
Filter the list by server port
Select All Ports or a single port from the Filter by Physical Server port list.