Virtual Connect modules 240
Corrective action: Configure FIPS mode on the module. To configure FIPS mode, see "Enabling FIPS
mode (on page 316)."
FC bay groups
In a multi-enclosure environment, all enclosures must have the same FC module configuration. For more
information, see "Multiple enclosure requirements (on page 62)."
Corrective action: Remove the incompatible module and replace it with the correct module for the
existing FC bay group.
In a c3000 enclosure, VC-FC modules are not supported in bay 2.
FC modules in multi-enclosure double dense domains
When using VC-FC modules, multi-enclosure double dense domains require similar and compatible
VC-FC modules in bays 5, 6, 7, and 8 in all enclosures. If a multi-enclosure double dense configuration
contains incompatible VC-FC modules in bays 5, 6, 7, or 8 in either the local or remote enclosures,
some or all of the compatible VC-FC modules in the remote enclosures might be designated
INCOMPATIBLE after import.
Corrective action:
a. Replace incompatible VC-FC modules with similar and compatible VC-FC modules in bays 5, 6, 7,
and 8 in all enclosures.
b. Power cycle any VC-FC module that still remains in an INCOMPATIBLE state.
Ethernet Bay Summary (General Information) screen
This screen provides a summary of the interconnect module status and general information. To remove a
module, see "Interconnect module removal and replacement (on page 275)."
The following table describes the rows within the Interconnect Bay Status table.
Row Description
Overall Status
Represents the worst condition of OA Reported Status, VC Status, and OA
Communication Status
Hardware Status
Component health status from the Onboard Administrator
VC Status
Component health status from the Virtual Connect Manager