User's Manual
Virtual Connect networks 113
You cannot reset a module if ports are configured on it. If ports are configured on the module you want to
reset, go to the Ports tab and edit the port to stop sampling and polling.
You can delete any receivers that have ports assigned from the given module. Deleting a receiver deletes all
of the ports assigned to that receiver.
The Status column displays the current status of the modules in the enclosure, and is not editable. Statuses:
• Running—sFlow monitoring is running.
• Not Running—sFlow monitoring is stopped for one of the following reasons:
o There is an internal error.
o The sFlow module IP is not configured.
o CPU usage is high.
• DHCP Lease Failed—DHCP is enabled for the sFlow module, but an IP address could not be retrieved.
• Duplicate IP Detected—A duplicate IP address has been detected.
• Unknown—VC is unable to determine the state.
sFlow Settings (Ports) screen
Use this screen to select the ports on which to collect sFlow data and to view settings on configured ports.
At least one module and one receiver must be configured to configure associated ports.
To configure an associated port, click Edit in the Action column.
To configure a port for sampling:
1. Select the Configure checkbox under Sampling.
2. Use the pull-down arrow to select the direction: Both, Ingress, or Egress.
3. Enter the Rate (256 to 16777216 packets).
4. Use the pull-down arrow to select a receiver.