Setup and Install

HP Virtual Connect Manager 93
Set a custom value for the Maximum FCoE Connection Speed. This value is the maximum speed for server
profile connections mapped to this fabric.
To see how logins are currently distributed on the VC-FC module, navigate to the Interconnect Bays Status
and Summary screen and select the desired VC-FC module. A new Uplink Port column is added to the Server
Ports section of the screen.
To see how logins are currently distributed on the VC FlexFabric module, navigate to the Interconnect Bays
Status and Summary screen and select the desired VC FlexFabric module. A new SAN Uplink Port column is
added to the Server Ports tab.
You can also see how logins are currently distributed on the VC-FC or FlexFabric modules by logging in to the
upstream FC SAN fabric switch.
Fabric summary
This screen lists the summary of fabrics that are created.
Select Create more fabrics to define additional fabrics, or Done if you have defined all available fabrics.