Setup and Install

Installation 23
Because Virtual Connect communicates with other components through the Onboard Administrator, special
considerations are required when using EBIPA with Virtual Connect Ethernet modules:
The Onboard Administrator must be on the same IP subnet as all Virtual Connect modules.
The Onboard Administrator IP address must be set properly before changing the IP addresses of the
Virtual Connect modules.
Stacking Links
Stacking links are used to add VC-Enet modules to a VC domain. This feature enables any server NIC
physically connected to a VC module to be connected to any Ethernet network. By using stacking links, a
single pair of uplinks can function as the data center network connections for the entire Virtual Connect
domain.
Observe the following guidelines:
Use uplink ports to connect modules to data center switches or stack VC-Enet modules and enclosures.
Virtual Connect does not support stacking for FC modules. Each VC-FC module or FlexFabric module
configured to carry Fibre Channel or FCoE traffic requires uplink connections to the external FC SAN
environment.
The following modules only support external stacking for Ethernet traffic:
o HP VC FlexFabric 10Gb/24-port
o HP VC FlexFabric-20/40 F8
o HP VC Flex-10/10D
When these modules have ports configured to carry Fibre Channel or FCoE traffic, those ports do not
support stacking.
Observe the following information when Ethernet modules are horizontally-adjacent:
o HP VC Flex-10 Enet modules
Uplink ports X7 and X8 form internal stacking links between the modules when left unpopulated.
o HP VC FlexFabric 10Gb/24-Port modules
Uplink ports X7 and X8 form internal stacking links between the modules when left unpopulated.
o HP VC Flex-10/10D Modules
Ports X11, X12, X13, and X14 are dedicated internal stacking links.
o HP VC FlexFabric-20/40 F8 Modules
Ports X9 and X10 are dedicated internal stacking links.
Virtual Connect automatically detects when one VC-Enet module port is connected to another VC-Enet
module port within the domain and changes the port ID indicator color to amber to indicate a stacking
link.
All VC-Enet modules within the Virtual Connect domain must be interconnected. Any combination of
1Gb and 10Gb cables can be used to interconnect the modules. If connecting HP VC FlexFabric-20/40
F8 modules, 40Gb stacking cables can be used.
ISL ports provide stacking links between horizontally adjacent modules.
In partially stacked domains, the combination of a stacking link and horizontally-adjacent Enet modules
is considered a logical interconnect. Logical interconnects are formed in horizontal and primary slice
stacking modes.