Release Notes

Issues and workarounds 7
If a Virtual Connect 8Gb 24-Port FC Module and a Brocade 8 Gb SAN Switch for HP BladeSystem
c-Class are in the same enclosure, collecting a VC supportdump may cause the Brocade 8 Gb SAN
Switch for HP BladeSystem c-Class to panic.
Server ports changed from factory MAC addresses to VC MAC addresses with a pass-through module.
The following Cisco cables QSFP-H40G-ACU7M and QSFP-4SFP10G-CU5M show up as
Unrecognized instead of Linked (non-HP) for all connections except for when the splitter end is attached
to the FlexFabric 20/40 module, in which case it should show Not Linked.
Addressed CVE-2013-2566.
LLDP ChassisId TLV is not the VC module MAC Address. New VCM CLI command 'set lldp
enhancedTlv=false' allows ChassisId TLV to be the MAC Address of the VC module.
Maximum characters allowed in LDAP Group Description when using CLI is now set to 20 characters,
the same limitation as the GUI.
After a VC firmware update or VC module reboot, some downlink ports could intermittently show DCC
as unavailable.
Mismatch between sysName in SNMP and system name TLV in LLDP.
When using VCSU manual activation on HP VC FlexFabric 10Gb/24-port Modules during a firmware
update, hosts will not be able to log in through the FC uplinks after the standby module is
activated/rebooted until a VCM failover is initiated or if the primary module is activated/rebooted.
Issues and workarounds
Issue
The text size of the Set/Clear SSH Key buttons are not displayed properly under SSH Key Administration in
Internet Explorer 11.
Workaround
Set a readable text size in Internet Explorer. Click on ViewText sizeSmaller.
Issue
The “show config” command generates a network map configuration using a list of server VLAN IDs from the
“server-port-map-range” command. The “show config” output displays “Network not found” for multiple
networks where the server VLAN ID is different from the SUS VLAN ID.
Workaround
Identify the specific “server-port-map-range” command in the “show config” output, and then replace it
with the “server-port-map” command and appropriate network name and VLAN ID.
Issue
When users with Network Role privileges finish the Network Setup Wizard, the final page displays a ”Start
Fibre Channel Setup Wizard” checkbox. After clicking the Finish button to proceed, VCM returns a NULL
error.
Workaround
In the top banner of the GUI, click the 'Home' link to exit the wizard and return to the home screen.