User's Manual

Configuring the Virtual Connect domain using the CLI 196
Deleting a profile, moving a profile to a different device bay, or unassigning a profile from the existing
bay
Making modifications to a profile that affect settings on the server blade; for example, PXE
enable/disable, changing the number of connections, or changing Fibre Channel boot parameters
Resetting the server blade to factory defaults from the RBSU
If the server blade is reset to factory defaults from the RBSU, perform the following:
a. Power down the server blade using the Momentary Press option.
b. Re-apply the VC server profile.
c. Power up the server.
The following operations do not require the server blade to be powered down:
Changing the network connected to an already defined Ethernet port
Changing the Fabric connected to a Fibre Channel port
Changing the speed of a Fibre Channel port
Assigning or unassigning server profiles, if server factory defaults are used for MAC addresses and
WWNs, BIOS Fibre Channel boot settings are used, and PXE is not being enabled or disabled (USE
BIOS for all network connections).
Exceptions for Flex-10 and FlexFabric 20 connection changes are specified in the following sections.
Flex-10 and FlexFabric 20 connection changes that require power down
Always power down server blades with Flex-10 connections in the following instances:
Adding a connection that is mapped to a Flex-10 or FlexFabric 20
Removing a connection that is mapped to a Flex-10 or FlexFabric 20
Assigning a profile to a server that maps Flex-10 or FlexFabric 20 connections
Unassigning a profile with Flex-10 or FlexFabric 20 connections
Flex-10 connection changes that do not require power down
With Virtual Connect v2.10 and higher, it is not necessary to power down a server blade with Flex-10
connections in the following instances:
Changing a connection's network:
o From a single network to another single network
o From a single network to multiple networks
o From multiple networks to a single network
Modifying the networks or VLAN IDs in a connection with multiple networks
With Virtual Connect v2.30 and higher, it is not necessary to power down a server blade with Flex-10
connections in the following instances:
Changing a connection's network:
o From "unassigned" to a single network
o From a single network to "unassigned"
o From "unassigned" to multiple networks
o From multiple networks to "unassigned"