Technical data
Intermittent Errors Might OccurWith the Use of
DataDigests (5108515)
Internet SCSI (iSCSI) targets might report cyclic redundancy check (CRC) errors if DataDigests
are enabled. User applications that update input/output buers after transmitting to the iSCSI
initiator might cause a miscalculation of the CRC. When the target responds with a CRC error,
the iSCSI Initiator retransmits the data with the correct DataDigest CRC. Data integrity is
maintained. However, data transfer performance is aected. No error message is displayed.
Workaround: Do not use the DataDigest option.
Conguring Multiple Tunnels BetweenTwo IP Nodes
With Filtering Enabled Might Result in Packet Loss
(4152864)
If you congure multiple IP tunnels between two IP nodes, and enable
ip_strict_dst_multihoming or other IP lters, packet loss might result.
Workaround: Choose one of the following:
■
First, congure a single tunnel between the two IP nodes. Add addresses to the tunnel by
using the ifconfig command with the addif option.
■
Do not enable ip_strict_dst_multihoming on tunnels between two IP nodes.
Security Issues
The following security issues applies to the Solaris 10 release.
KDC Daemons Fail to Start (6623803)
If Kerberos is congured to use the LDAP backend for the Kerberos database, krb5kdc/kadmind
will fail to start when run through SMF. krb5kdc/kadmind will be in the maintenance state.
Workaround: Type the following command:
echo "something" >/var/krb5/principal
Security Issues
Solaris 10 5/08 Release Notes • April 200884