Self-Test Failure During a Connect Sequence
Remove the board from the system as soon as possible if the following error message is
displayed during a DR connect sequence:
cfgadm: Hardware specific failure: connect failed: firmware operation error
The board has failed self-test, and removing the board avoids possible reconguration errors
that can occur during the next reboot.
The failed self-test status does not allow further operations. Therefore, if you want to retry the
failed operation immediately, you must rst remove and then reinsert the board.
Known Bugs
The following list is subject to change at any time.
Network Device Removal Fails When a Program Is Holding the Device
Open (5054195)
If a process is holding open a network device, any DR operation that would involve that device
fails. Daemons and processes that hold reference counts stop DR operations from completing.
Workaround: As superuser, perform the following steps:
1. Remove or rename the /rplboot directory.
2. Shut down NFS services.
# sh /etc/init.d/nfs.server stop
3. Shut down Boot Server services.
# sh /etc/init.d/boot.server stop
4. Perform the DR detach operation.
5. Restart NFS services.
# sh /etc/init.d/nfs.server start
6. Restart Boot Server services.
# sh /etc/init.d/boot.server start
Dynamic Reconguration on Sun Enterprise Midrange Systems
Chapter 3 • System-Specic Issues 117