Installation Guide

Chapter 6. Administration of the Telecommuting Module
Save/Load Configuration
Here, you work with the preliminary and permanent configurations, save them and load new configurations from
previously saved configurations.
Test Preliminary Configuration
When Apply configuration is pressed, the Telecommuting Module will test the configuration before you make it
permanent.
During test, the Telecommuting Module waits for you to press one of the three buttons displayed. If you never see
the three buttons, something in your preliminary configuration (now tested) is wrong, which makes it impossible for
you to access the configuration web interface.
Duration of limited test mode
Here, you enter the time limit for the testing. If you do not press any button within this time, the Telecommuting
Module will assume that some part of your preliminary configuration makes connecting impossible. When the
timeout is reached, the Telecommuting Module automatically reverts to the old permanent configuration. If this
occurs, you will be informed when trying to press a button.
Apply configuration
Saves the preliminary configuration to the permanent configuration and puts it into use. You can test your
preliminary configuration before finalizing it.
Three buttons are displayed during the test:
Save configuration saves your preliminary configuration to the permanent configuration and puts it into use.
Continue testing shows a new page with only the other two buttons.
Revert cancels this test of the preliminary configuration without saving.
If you do not press any button within the time limit, the Telecommuting Module will revert to the old permanent
configuration, just as if you had pressed Revert. This is useful if you happen to configure your Telecommuting
Module so it isn’t accessible from your browser.
After the timeout, pressing either of the three buttons will show a new page which will inform you that the test run
was aborted.
Restarting the Telecommuting Module by cycling the power also cancels the test.
Backup
All configurations can be saved to and loaded from diskette or file. This does not affect the permanent configuration.