RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX Release Notes
RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX
Page 64 AA–R1ZZE
−
TE
e. The redirection is accomplished by the following hwmgr commands:
# hwmgr -redirect scsi -src 3 -dest 7
hwmgr: Redirect operation was successful
# hwmgr -redirect scsi -src 4 -dest 8
hwmgr: Redirect operation was successful
Final result, and proof that all devices are reachable:
# hwmgr -view devices
HWID: Device Name Mfg Model Location
----------------------------------------------------------
4: /dev/kevm
27: /dev/disk/floppy0c 3.5in floppy fdi0-unit-0
34: /dev/disk/dsk0c DEC RZ28 (C) DEC bus-0-targ-1-lun-0
35: /dev/disk/dsk1c DEC RZ26L (C) DEC bus-0-targ-2-lun-0
36:/dev/disk/cdrom0c DEC RRD44 (C) DEC bus-0-targ-5-lun-0
37: /dev/disk/dsk2c DEC HSZ50 (C) DEC bus-1-targ-3-lun-0
38: /dev/disk/dsk3c DEC HSZ50 (C) DEC bus-1-targ-3-lun-1
39: /dev/disk/dsk4c DEC HSZ50 (C) DEC bus-1-targ-6-lun-0
40: /dev/disk/dsk5c DEC HSZ50 (C) DEC bus-1-targ-6-lun-1
42: /dev/cport/scp1 HSZ50 (C) DEC bus-1-targ-3-lun-0