RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX Release Notes
Release Notes
AA–RMBXA
−
TE Page 9
Table 2-2 Supported Tape Drives - continued
Device
Capacity
G= Gigabytes
T= Terabytes
Minimum
Microcode
Version
Minimum
Hardware
Version Notes
DS-TZ89N-TA 35/70 141F A01 1,3,4,5,6
DS-TL890 560/1120 3.23 robot/V55
drive
A01 1,2,3,4,5
DS-TL891 350/700 3.23 robot/V55
drive
A02 1,2,3,4,5
DS-TL892 350/700 3.23 robot/V55
drive
A02 1,2,3,4,5
DS-AIT35-VW 35/70 4.03 A01 5,6,7
Table 2-2 Notes:
1.
Requires 0.2 meter SCSI-1 to SCSI-2 transition cable, Compaq internal part number 17-
03831-01 for DWZZA-AA, and Compaq part number 17-04367-01 for SSB DWZZA-
VA and DWZZB-VW.
2.
Requires SWXA2 single-ended to differential SCSI signal converter.
3.
Capacity values represent compressed data. The compression factor is device dependent
based on individual device algorithms.
4.
Cannot read TK50, TK70 or TZ30 formatted tapes.
5.
Requires a KZPSA or PMAZC host adapter.
6.
Tape device code load is supported.
7.