RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX Release Notes

Release Notes
AARMBXA
TE Page 49
NOTE
After restart, the controller will not allow you to enter any CLI
commands for approximately 60 seconds. This delay does not
affect unit availability to the host. The delay provides time for
the controller internal operations to complete before user
commands can change configuration.
NOTE
The controller will initialize and the Reset button will flash at
an approximate once per second rate when ready for operation.
7. Replace the ESD cover on the controller, pushing the locking pins to
secure them in place.
8.
Mount the storage units on the host. Resume I/O activity to the controller.
NOTE
You can identify the version of the HSOF software that is
currently loaded in the controller by entering a
SHOW THIS_CONTROLLER command at the CLI prompt.
9.2 Dual-Redundant Upgrade
Before you can begin the Dual-Redundant upgrade you will first need to
determine which one of the following two upgrade procedures you will
perform:
Dual-Redundant Controller Rolling Upgrade
Or
Dual-Redundant Controller Shutdown Upgrade