5.8.1.2.2 Controller Not Factory Initialized (No Configuration
Data)
With this situation, the new controller does not search the
devices in the subsystem for a saved configuration and the
controller is not brought on-line. The CLI command: SET
this_controller INITIAL_CONFIGURATION must be entered to
allow the configuration saved on a storageset to be brought in.
5.8.1.2.3
Controller Has Prior Configuration Data
With this situation, the controller software displays many errors
in finding the disks it assumes is part of the configuration. The
CLI command: SET this_controller
INITIAL_CONFIGURATION must be entered to clear the
incorrect configuration from NVMEM and bring in the proper
configuration from the container that has it stored. See the
HSZ40 Array Controller HSOF V3.1 CLI Reference Manual for
additional details.
CAUTION
Do not enter any other SET this_controller command other than a
SET this_controller INITIAL_CONFIGURATION. Entering another
type of SET this_controller command may change the configuration
data stored in the controller NVMEM. When this happens, the
software initiates an update of the saved configuration to the
container(s) in which the configuration was saved, thereby
destroying the proper saved configuration