RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX Release Notes
Release Notes
AA–RMBXA
−
TE Page 13
NOTE
Although some of the above listed Devices may have been supported
in previous releases, all of these Devices have been classified as “new”
for the HSOF V3.7 Software Release. Please see Section 2.4 for
additional information on Device Support.
3.3 Issue Resolutions
This section addresses issues that occurred in a previous release of the HSOF
software and have been resolved in the HSOF V3.7 release. The issues
addressed by HSOF V3.7 Software are as follows:
• A rare occurrence of a disk device responding to TEST UNIT READY but
not to any subsequent commands
• A rare occurrence of the controller experiencing a reset with the last
failure code of 43130100 when using scripts that perform the
configuration/de-configuration of storagesets
• A rare occurrence in which an unusual drive error caused RAIDsets to
suspend activity on the controller. This situation could occur when a drive
became busy and as a result, would tie up the port
• An occasional problem with failover on a dual-redundant controller pair
during certain unusual cache battery states.
• An occasional issue of a disk entering a mount verification timeout state
when changing the preferred path on a stripeset.
• A rare occurrence of a drive error causing an “online with lost data”
message and a spareset lockup or I/O failure when a drive was being
added to the storageset
• A rare occurrence in which multiple Bad Block Replacements in the same
data transfer from a mirrorset cause a Unit Attention message to be sent to
the host. This may lead to Compaq Tru64 UNIX V4.0x perception of an
I/O failure, resulting in various host effects. The correction for this
problem requires installation of both HSOF SoftwareV3.7 and a patch kit
to Compaq Tru64 UNIX V4.0x. See Section 7.2, Compaq Tru64 UNIX
Patch Kits for Issue Resolution, to obtain information on Compaq Tru64
V4.0 versions and their corresponding patch kits