HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and Configuration Guide

Table Of Contents
FC Configuration Procedures
5–10 HSG80 ACS Solution Software Version 8.7 for Compaq Tru64 UNIX Installation and
Configuration Guide
Your host computer should report one CCL device special file for each HSG80
configured.
Setting Up a Controller Pair
Power Up and Establish Communication
1. Connect the computer or terminal to the controller as shown in Figure 5–1. The
connection to the computer is through the COM1 or COM2 ports.
2. Turn on the computer or terminal.
3. Apply power to the storage subsystem.
4. Configure the computer or terminal as follows:
9600 baud
8 data bits
1 stop bit
—no parity
no flow control
5. Press Enter. A copyright notice and the CLI prompt appear, indicating that you
established a local connection with the controller.
Cabling a Controller Pair
The cabling for a controller pair is shown in Figure 5–3.
NOTE: It is a good idea to plug only the controller cables into the switch. The host cables are
plugged into the switch as part of the configuration procedure (“Configuring a Controller Pair
Using CLI,” page 5–11).