HP Tru64 UNIX Technical Updates for the Version 5.1B and Higher Operating System and Patches (February 2010)

Correction to Configuration Cloning Restrictions (Nov. 2002)
In Section 7.4 of the Installation Guide Advanced Topics, the second bullet explains that software
patches are not cloned. There are typographical errors in the procedure to use if your model
system has already been patched; the -f option is incorrect and should be -force. The following
is the corrected text:
Software patches are not cloned. The reason for this restriction is that installed patches
change serial numbers, which will cause validation errors when the config.cdf file is
applied to the target system. The config.cdf file you create must be created from a model
system that has not been patched.
If the model system has already been patched, there are two alternatives you can follow,
although they are not recommended:
Create the config.cdf from the patched system anyway. Use the -force option when
applying the config.cdf file to the target system to force the config.cdf onto the
target system. For example, at the target system, enter:
# sysman -clone -apply -force config.cdf
Then, at the newly cloned target system, create another config.cdf to use for cloning
additional systems. The new config.cdf will contain the correct checksums, and
cloning other systems from this file will be valid.
Caution:
The -force option to force a CDF onto a target system is typically used for internal
debugging purposes. Be aware that should the config.cdf contain additional problems
other than the patched model system issue, forcing the CDF could cause problems on
the target system from which there may be no recovery.
Use the Update Installation process to update the patched model system to the next
version of the operating system, if the next version has been released, thereby bypassing
the patch issue.
Other Documentation Issues
HSZ70 Storage Array Controller is Supported on Tru64 UNIX Version 5.1B (May 2003)
The Tru64 UNIX Version 5.1B Release Notes incorrectly announced the retirement of the HSZ70
storage array controller in conjunction with the release of Version 5.1B of the Tru64 UNIX
operating system.
The HSZ70 is supported with Version 5.1B. The controller driver software is included on the kit,
and the Version 5.1B documentation includes troubleshooting information for the HSZ70.
DEC Ada Retirement (May 2003)
DEC Ada was retired in March, 2000. The Tru64 UNIX Version 5.1B Release Notes incorrectly
states that DEC Ada (UPI - 0HM) and DEC Ada PDO (UPI - 0VS) will be retired in a future release
of the operating system.
Motif 1.2 Input Methods Work (Sept. 2004)
The README file included with the Motif 2.1 package inaccurately states that input methods
that “currently work will not work with Motif 2.1.” In fact, input methods will work in most
cases. When Motif 2.1 is installed, the README file is available at /usr/opt/motif2.1/READM.
Documentation Corrections 47