Fixes an infinite loop under certain circumstances in cms_do_mount_rpc().
Added option to unset all flags for a service in /etc/clua_services.
Corrects a reference count issue in the KGS subsystem.
Fixes node panic with ics_unable_to_make_progress: netisrs stalled, though
netisr thread was not actually stalled.
Provides a fix for a domain panic caused by hung IOs on a busy or faulty disk drive. The
panic can happen after all but one path to the disk drive being disabled then re-enabled.
Corrects a problem where a 'local open' on a previously opened tape drive results in an
erroneous "no such device" message.
Provides a fix for a cluster boot-time hang, caused by a fault quorum disk.
Fixes multiple issues with RDG(Reliable DataGram) component in a LAN cluster.
Fixes an issue with CFS failover subsystem where, under certain domain configurations
failover process may hang.
Fixes a problem with fuser(8) where usage of the -a option leaves the filesystem incapable
of unmounting even if no files or directories on the filesystem are in use.
Fixes a problem where, under certain circumstances, a close on socket of type AF_UNIX may
result in a system panic.
Provides enhancements to the DRD trace framework.
Optimize the performance of ics0 interface in a LAN cluster.
Fixes an issue with aliasd routing in a cluster.
Avoids panic due to bad quorum disk during boot process.
Fixes an issue wherein Internode Communication Subsystem panics when it receives
messages for an unknown service.
Updates volstat utility and kernel to report cluster-wide LSM statistics.
Add support in cluster alias to handle socket unlisten.
PATCH 28002.00
TCRMAN540
Provides the latest reference pages for sys_attrs_cfs(5), sys_attrs_clubase(5), and sys_attrs_rdg(5).
Updates clu_alias.config(4) and exports.aliases(4) reference pages.
Updates sys_attrs_icsnet(5) reference page to reflect icsnet_mtu attribute.
Updates the following reference pages: clua_services(4), cfsd.conf(4), sys_attrs_ics_ll_tcp(5)
Updates the following reference pages: imcs(1), dlm_rd_collect(3), dlm_rd_validate(3),
imc_rderrcnt(3), sys_attrs_cms(5), sys_attrs_drd(5), sys_attrs_icsnet(5)
Patch 27001.00
TCRBASE540
Eliminates numerous panics and hung devices by fixing drd so it no longer accesses a device
that has a deletion pending or in progress.
Fixes an RM simple lock timeout issue that may occur in noisy Memory channel rails.
Enhances the error message generated when the clu_bdmgr command cannot access a
member boot disk.
Fixes a configuration issue found in non-CAM devices and CD_ROM devices.
Fixes the cause of potential cluster hangs during some Memory Channel hardware failures
that result in an MC rail failover.
Fixes the CFS AIO write error path so the I/O completion steps are not repeated.
Fixes a flaw in CFS file locking code that causes a "vrele: bad ref count" panic.
Fixes the cause of an assertion failure in cfs_vnops.c.