RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX Release Notes

Release Notes
AAR1ZZE
TE Page 73
e. Connect the CLI interface to one of the controllers and perform
SHOW <UNIT> command for the unit with the root device (D600 in case of
the example).
HSZ> show d600
LUN Uses
----------------------------------------------------------
D600 DISK600
...
State:
ONLINE to this controller
Not reserved
PREFERRED_PATH = THIS_CONTROLLER
...
If the output shows that the unit is ONLINE to this controller
(as is the case in this example), then THIS_CONTROLLER is
the master controller.
If the output shows that the unit is ONLINE to the other
controller, then OTHER_CONTROLLER is the master
controller.
2.
Halt all host I/O activity to the controller and prepare the host system for a
controller shutdown using the appropriate procedures for your operating
system.
3.
Establish a local connection to the controller through the maintenance port
of the controller.
4.
Enter the SET NOFAILOVER command to take the controllers out of dual-
redundant (failover) mode.
$ SET NOFAILOVER
5. Shutdown the controller with the following command:
SHUTDOWN THIS_CONTROLLER
CAUTION
Failure to shut down the controller in this step could result in
problems with RAIDsets and cache when the controller is reset.