RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX Release Notes

RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX
Page 64 AAR1ZZE
TE
e. The redirection is accomplished by the following hwmgr commands:
# hwmgr -redirect scsi -src 3 -dest 7
hwmgr: Redirect operation was successful
# hwmgr -redirect scsi -src 4 -dest 8
hwmgr: Redirect operation was successful
Final result, and proof that all devices are reachable:
# hwmgr -view devices
HWID: Device Name Mfg Model Location
----------------------------------------------------------
4: /dev/kevm
27: /dev/disk/floppy0c 3.5in floppy fdi0-unit-0
34: /dev/disk/dsk0c DEC RZ28 (C) DEC bus-0-targ-1-lun-0
35: /dev/disk/dsk1c DEC RZ26L (C) DEC bus-0-targ-2-lun-0
36:/dev/disk/cdrom0c DEC RRD44 (C) DEC bus-0-targ-5-lun-0
37: /dev/disk/dsk2c DEC HSZ50 (C) DEC bus-1-targ-3-lun-0
38: /dev/disk/dsk3c DEC HSZ50 (C) DEC bus-1-targ-3-lun-1
39: /dev/disk/dsk4c DEC HSZ50 (C) DEC bus-1-targ-6-lun-0
40: /dev/disk/dsk5c DEC HSZ50 (C) DEC bus-1-targ-6-lun-1
42: /dev/cport/scp1 HSZ50 (C) DEC bus-1-targ-3-lun-0