RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX Release Notes

Release Notes
AAR1ZZE
TE Page 43
8.2.2 SET unit-number
Referring to the section titled Set unit-number in the HSZ50 Array Controller
HSOF Version 5.1 CLI Reference Manual on page 2-80, the below example
was included in error. Please strike through this example.
TO SET UNIT T47 TO 1600 BPI
CLI> SET T47 DEFAULT_FORMAT=1600BPI_9TRACK
8.3 Array Controller HSOF V5.1 Service Manual
8.3.1 Software Installation
Please see section 9.0 Software Installation in this document. Section 9.0
provides the specific procedures needed to install your HSOF V5.7 Software.
The information in this section can be used in conjunction with the information
found in the HSZ50 Array Controller HSOF V5.1 Service Manual, Chapter 3
Installing and Upgrading, pages 3-3 through 3-21.
8.3.2 HSUTIL Procedure
Please insert the following procedure in the HSZ50 Array Controller HSOF
V5.1 Service Manual, Chapter 3 Installing and Upgrading, page 3-36 after
the section Considerations for Installing New device Firmware.
Use the below procedure to upgrade firmware with HSUTIL.
1.
Connect a local terminal to the controller that accesses the device you
want to upgrade.
2. Configure a single-disk unit.