6.8 Running CONFIG or CFMENU Utilities During Backup or
Copy Operations
Do not run the CONFIG or CFMENU utilities during a tape backup or copy
operation.
6.9 Changing Host Adapter Types
If for some reason you change your host adapter and maintain the same node
number, you MUST restart your controller or controllers.
6.10 Limits on the Total Number of Storagesets
The following limits apply to storagesets configured on a single controller or
dual-redundant controller configuration:
A mirrorset can have a maximum of 6 members
A stripeset or RAIDset can have a maximum of 14 members
There can be a maximum of 20 mirrorsets or RAIDsets or both
There can be a maximum of 30 storagesets including RAIDsets,
mirrorsets, and stripesets
There can be a maximum of 32 physical device members total for a unit
There can be a maximum of 4 partitions per disk or storageset
There can be a maximum of 256GB per storageset
NOTE
When building stripesets with drives of capacity 4 GB or greater, the
largest stripeset that can be built contains 11 members.
6.11 CLONE Utility Constraints
The CLONE utility cannot be used with partitioned units. When running the
CLONE utility in a dual-redundant controller configuration, do not issue any
CLI commands to devices that are involved in the clone operation.