RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX Release Notes

RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX
Page 54 AARMBXA
TE
NOTE
Wait for the following to happen before continuing:
The Reset button flashes at an approximate once per second rate
and
The maintenance terminal displays a message that finishes with
other controller restarted.
6. Read the status of other controller by issuing the following command:
SHOW OTHER_CONTROLLER.
NOTE
When the
SHOW OTHER_CONTROLLER command verifies that the
other controller restarted,
it is safe to continue.
7. Replace the ESD cover on other controller and push the locking pins to
secure it.
8.
When other controller has completely rebooted, move the local
connection to the maintenance port of other (newly upgraded) controller,
which will cause the newly upgraded controller to become this
controller.
Issue the
SHOW THIS_CONTROLLER command.
The resulting display will show that the controllers are misconfigured due
to the differing product IDs.
9.
Issue the SET NOFAILOVER command to shutdown the other controller
still containing old software. This will cause the other controller to shut
down and devices to fail over to this controller.
10.
Observing all notes and caution statements in steps 2 through 7 remove the
old program card, insert the new one, and reset other controller to start
it.
11.
When the second controller has restarted as described in Step 6, issue the
SET FAILOVER COPY=controller command.
Either THIS or OTHER may be used as the source in the COPY=
parameter since both controllers have already been updated.