RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX Release Notes

RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX
Page 38 AARMBXA
TE
There are two procedures that may be used to accomplish the above three
steps. Compaq recommends the first procedure.
7.8.1 Using AC switch
1. Turn off AC switch after EMU alarm sounds on extended cabs.
2.
Turn on AC switch on extended cabs.
3.
Turn on AC switch on Master Cab.
7.8.2 Using EMU/PVA
1. On extended cabs, wait for EMU alarm to sound, turn off EMU alarm,
then press and hold PVA switch until the cab shuts down.
2.
Press EMU button on extended cabs.
3.
Press EMU button on Master Cab.
7.9 Using the CLI and CF Menu Simultaneously in a Dual
Configuration
When in a dual configuration do not issue a simultaneous CLI command on
one controller and a CFMENU command on the other controller. This can
cause a deadlock situation between the two controllers while each waits for a
CLI lock.
7.10 Changing the Preferred Access Device
To change the preferred access device for the SWCC UNIX Agent, perform
one of the following procedures:
Directly edit the storage.ini file which is kept in the /usr/opt/SWCC500/etc
directory. It is an ASCII file, and any ASCII editor may be used
Or
Delete/rename the existing storage.ini file. When the Agent is restarted, a
new storage.ini file is created with default names and monitor intervals
Or
Delete the existing storage.ini file and run the swcc_config utility. Select
option 2 (Modify Storage Subsystem Information) and select the add
option. This will rescan the device and will use the current access device
Once the storage.ini file has been changed, the user must stop and restart the
Agent in order for the changes to take effect.