RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX Release Notes
Release Notes
AA–R1ZZE
−
TE Page 45
5. Enter 2 or 3 from the HSUTIL menu.
Example:
2
6. Choose the single-disk unit as the source disk for the download. You will
see:
Available single device units on this controller include:
Unit Associated Device SCSI Product ID Current Device
Rev 0 DISK10500 RZ1BB-CS (C) DEC 0844
The HSUTIL Menu will ask:
Which unit is the code to be loaded FROM?
Example: 0
7. Enter the starting LBN of the firmware image (Usually LBN 0)
or
Press Enter for the default [LBN 0]
Example:
[LBN 0]
8. Enter the product ID of the device you want to upgrade. This ID
corresponds to the product information that’s reported in the “Type”
column when you issue the SHOW DISK command.The HSUTIL menu
will ask the following:
What is the SCSI PRODUCT ID of the device that you want code
load TO?
Example: rz1bb-cs
HSUTIL lists all devices that correspond to the product ID you entered:
Unattached devices on this controller include:
Device SCSI Product ID Current Device Rev
DISK20500 RZ1BB-CS (C) DEC 0844
DISK10400 RZ1BB-CS (C) DEC 0844