RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX Release Notes
RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX
Page 44 AA–R1ZZE
−
TE
NOTE
In the steps that follow, you will copy the firmware image to
this unit, then use HSUTIL to distribute it to the devices you
are upgrading. This unit must be a newly initialized disk with
no label or file structure to ensure that the firmware image
resides in contiguous blocks starting from LBN 0 or another
known LBN. Additionally, write-back caching must be disabled
(see HSZ50 Array Controller HSOF Version 5.1 CLI Reference
Manual). See the HSZ50 Array Controller HSOF Version 5.1
Configuration Manual for instructions on configuring a single-
disk unit.
See the Firmware Release Notes for details and exceptions to
the code load process.
3. Copy the firmware image to the single-disk unit that you configured in
Step 2. The firmware image must begin at a known LBN (usually 0) and
must be contiguous. See the documentation that accompanied your host’s
operating system for instructions on copying firmware images to a disk
drive.
CAUTION
You must quiesce the host load before running HSUTIL or
damage to the storage device can occur.
4. Start HSUTIL with the following command:
HSZ> RUN HSUTIL
HSUTIL displays the following:
*** Available functions are:
0. EXIT
1. FORMAT_DISK
2. DEVICE_CODE_LOAD_DISK
3. DEVICE_CODE_LOAD_TAPE