RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX Release Notes

RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX
Page 34 AAR1ZZE
TE
7.0 Avoiding Problem Situations
In certain situations, you may experience unusual controller behavior.
Paragraphs 7.1 through 7.9 present information to help you avoid such
situations and to recover from them if they occur:
HSUTIL Program Failure During a Code Load Firmware Upgrade
Compaq Tru64 UNIX Patch Kits for Issue Resolution
CLEAR_ERRORS LOST_DATA Command
Only One Switch per CLI Command Recommended
Hot Swapping Devices
Write-Back Cache Battery Replacement
Restoring Power after Emergency Cab Shutdown
Using the CLI and CF Menu Simultaneously in a Dual Configuration
Changing Preferred Access Device
7.1 HSUTIL Program Failure During a Code Load Firmware
Upgrade
As noted in Section 3.3, in a rare occurrence the HSZ50 controller may not be
able to use the HSUTIL program to perform a code load firmware upgrade to
TZ87/88/89 tape drives or any associated Automated Tape Library. In such a
case the HSUTIL program refuses to perform the upgrade because it
incorrectly determines that there is a tape present in the target tape drive when
there is none.
The HSZ50 controller has the capability to perform firmware upgrade "code
loads" to tape drives included in its storage subsystem configuration. This code
load capability is manually accessed via the HSUTIL program in the
controller. The code load procedure requires that there be no tape in the drive.
In rare circumstances, HSUTIL in these controllers incorrectly determines that
there is a tape in the target drive, and refuses to perform the firmware upgrade.