RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX Release Notes

RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX
Page 10 AAR1ZZE
TE
Table 2-3 Supported Solid State Devices
Device
Capacity in
Gigabytes
Minimum
Microcode
Version
Minimum
Hardware
Version Notes
EZ31-VW 0.134 V064 A01 2, 3
EZ32-VW 0.268 V064 A01 2, 3
EZ51R-VA 0.10 V096 D01 2, 3
EZ54R-VA 0.42 V109 C02 2, 3
EZ58R-VA 0.85 V110 D01 1, 2, 3
EZ64-VA 0.475 V064 A01 2, 3
EZ64-VW 0.475 V070 A01 2, 3
EZ69-VA 0.950 V064 A01 2, 3
EZ69-VW 0.950 V070 A01 2, 3
EZ454 .536 Y018 A01 2, 3
EZ832 3.2 Y018 A01 2, 3
EZ41 0.134 V012 A01 2, 3
EZ42 0.268 V012 A01 2, 3
EZ51 .107 V109 C02 2, 3
EZ54 .428 V109 C02 2, 3
EZ705 0.536 V012 A01 2, 3
EZ711 1.1 V012 A01 2, 3
EZ716 1.6 V012 A01 2, 3
Table 2-3 Notes:
1.
Code load is not supported for these drives.
2.
Formatting supported for these drives.
3.
Do not warm-swap solid-state disk drives. Make sure power to the device shelf is turned
off before removing or inserting this device.