RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX Release Notes

RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX
Page 74 AARMBXA
TE
13. Follow the commands in the example below to correct the device files.
a.
Scan the SCSI interfaces to update the operating systems view of device
changes and then create new devices as necessary.
NOTE
Depending on the size of your configuration, the scan may take
several minutes to complete. The presence of tape devices will
further increase the delay to complete the scan. For this reason,
you may wish to use the -bus qualifier to specify the bus you
want to scan. The correct bus number can be determined by
examining the "location" field of the hwmgr -view devices
output.
# hwmgr -view devices
HWID: Device Name Mfg Model Location
----------------------------------------------------------
39: /dev/disk/dsk4c DEC HSZ40 (C) DEC bus-1-targ-6-lun-0
Issue the command for the appropriate bus (1 in this example).
# hwmgr -scan scsi -bus 1
b. In order to understand which devices need to be redirected to the newly
created devices, examine the current list of devices prior to rebooting the
system: