RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX Release Notes
RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX
Page 72 AA–RMBXA
−
TE
HSZ> show d600
LUN Uses
----------------------------------------------------------
D600 DISK600
...
State:
ONLINE to this controller
Not reserved
PREFERRED_PATH = THIS_CONTROLLER
...
If the output shows that the unit is "ONLINE" to this
controller (as is the case in this example), then
THIS_CONTROLLER is the master controller.
If the output shows that the unit is "ONLINE" to the other
controller, then OTHER_CONTROLLER is the master
controller.
2. Halt all host I/O activity to the controller and prepare the host system for a
controller shutdown using the appropriate procedures for your operating
system.
3.
Establish a local connection to the controller through the maintenance port
of the controller.
4.
Enter the SET NOFAILOVER command to take the controllers out of dual-
redundant (failover) mode.
$ SET NOFAILOVER
5. Shutdown the controller with the following command:
SHUTDOWN THIS_CONTROLLER
CAUTION
Failure to shut down the controller in this step could result in
problems with RAIDsets and cache when the controller is reset.
CAUTION
Before continuing, wait until the Reset button on the controller
stops flashing (lit continuously). This indicates that unwritten
data is flushed from the cache module.
6. Remove the PCMCIA program card ESD cover from the controller.