RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX Release Notes
Release Notes
AA–RMBXA
−
TE Page 69
NOTE
The controller will initialize and the Reset button will flash at
an approximate once per second rate when ready for operation.
7. Press and hold the Reset button while inserting the new program card.
Release the button after the new card is inserted.
NOTE
After restart, the controller will not allow you to enter any CLI
commands for approximately 60 seconds. This delay does not
affect unit availability to the host. The delay provides time for
the controller internal operations to complete before user
commands can change configuration.
NOTE
The controller will initialize and the Reset button will flash at
an approximate once per second rate when ready for operation.
8. Replace the ESD cover on the controller, pushing the locking pins to
secure them in place.
9.
Mount the storage units on the host. Resume I/O activity to the controller.
10.
Repeat steps 5 through 9 for the second controller.
11.
After you complete all of the above steps on both controllers, put the
controllers back into dual-redundant (failover) mode by entering the
following command:
$ SET FAILOVER COPY=CONFIGURATION_SOURCE