7. Replace the ESD cover on other controller and push the locking pins to
secure it.
8.
First pass through this procedure?
YES Move the maintenance port cable from this controller
to other controller maintenance port and repeat
procedure from step 2 to step 8 to replace the other
program card.
NOTE
Other controller switches with this controller”—the controller
that the maintenance port cable was plugged into originally
(this controller) becomes other controller for the second pass
through steps 28.
NO You have completed this procedure.
9.2.1.2
Procedure for Different Product IDs and Compaq Tru64
UNIX V4.0x for Dual-Redundant Rolling Upgrade
1. Establish a local connection to the controller through the maintenance port
of one of the controllers (this controller).
2.
Wait for the CLI prompt, and then shut down other controller by using
the following command:
SHUTDOWN OTHER_CONTROLLER
CAUTION
Before continuing, wait until the Reset button stops flashing
and stays lit continuously. This indicates that unwritten data is
flushed from the cache module.
3. Remove the program card ESD cover from other controller.
4.
Press and hold the controller Reset button while ejecting the old program
card. Release the button after the card is ejected.
5.
Press and hold the Reset button while inserting the new program card in
other controller Release the button after the new card is inserted.