RAID Array 410 HSZ40 HSOF Software Version 3.7 for Compaq Tru64 UNIX Release Notes

Release Notes
AARMBXA
TE Page 5
2.1 Hardware Support
HSOF Software Version 3.7 supports the following revisions or higher for the
RAID Array 410 and associated hardware:
RAID Array 410 controller modules, hardware revision A or B
HSZ40Bx and HSZ40Cx controller modules
Cache module Version 2, hardware revision A or B
BA350-MA controller shelf
BA350-Sx 8-bit SCSI device shelf
BA356-Sx wide shelf with 8-bit or 16-bit personality module (controller
operates in 8-bit mode only)
BA35x-HF power supply
2.2 Operating System Support
HSOF Software Version 3.7 on the RAID Array 410 is supported by the
following operating system versions:
Compaq Tru64 UNIX: V4.0d, V4.0e, V4.0f, V5.0, and V5.0a
The RAID Array 410 is supported on StorageWorks Systems equipped with the
PCI wide-differential SCSI adapter.
NOTE
If you are operating with any Compaq Tru64 UNIX versions
prior to V5.0, it is important to install HSOF software V5.7 on
your controllers before upgrading to Compaq Tru64 UNIX
versions 5.0 or higher.