HP Tru64 UNIX and TruCluster Server Version 5.1B-6 Patch Summary and Release Notes

Corrects a problem in which a DNS resolver routines never time out if interrupted by signals.
Provides an RFC3542 compliant implementation of IPv6 Advanced API.
Fixes a nonconcurrency issue for multithreaded applications calling popen() and certain
"FILE *" routines such as fread().
Fixes a deadlock condition in multithreaded applications that call fork() and other libc
callback routines such as exit handlers, __fini_* routines.
Corrects a condition in which multiple "Sorry" messages are issued by the su command
when multiple SIA mechanisms are in use (as when LDAP is configured for user accounts).
Improves the performance of times(3).
Enhances the fuser command to provide a cluster-wide query capability. A revised fuser(8)
reference page describes this enhancement.
Fixes a problem with glob() returning an incorrect match when directory permissions issues
exist.
Patch 27022.00
OSFDCMT540
Corrects several potential security vulnerabilities where, under certain circumstances, system
integrity may be compromised. These may be in the form of improper file or privilege
management.
Patch 27023.00
OSFDCMTEXT540
Corrects a potential security vulnerability where, under certain circumstances, system
integrity may be compromised. This may be in the form of improper file or privilege
management.
Patch 27026.00
OSFDOSTOOLS540
Corrects a potential security vulnerability where, under certain circumstances, system
integrity may be compromised. This may be in the form of improper file or privilege
management.
Corrects several security vulnerabilities.
Changes mcopy and mwrite so they can overwrite existing files.
Changes mtools so they can print appropriate error messages for nonprivileged users.
Standardizes the mformat prompt.
Patch 27028.00
OSFENVMON540
Fixes the envmond daemon to use EVM events for monitoring environmental events.
Fixes envmond to report redundant power supply restoration on systems that support
environmental monitoring through the sysconfig command.
Modifies the environmental monitoring facilities /usr/sbin/envmond and /usr/sbin/envconfig
to support the AlphaServer GS1280 system.
Updates envmond to ensure that the correct EVM events are being sent at the correct time.
Corrects a problem in which the environmental monitoring daemon does not display the
debug message "proceed ..." when the system is booted.
Corrects a problem in which envmond sets rc.config variable ENVMON_HIGH_THRESH
to a value read from kernel module if ENVMON_HIGH_THRESH is null.
Fixes issues with temperature threshold handling in envmond.
114 Tru64 UNIX Patches