RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX Release Notes

Release Notes
AAR1ZZE
TE Page 69
NOTE
The controller will initialize and the Reset button will flash at
an approximate once per second rate when ready for operation.
8. Replace the ESD cover on the controller, pushing the locking pins to
secure them in place.
9.
Mount the storage units on the host. Resume I/O activity to the controller.
10.
Repeat 5 through 9 for the second controller.
11.
After you complete all of the above steps on both controllers, put the
controllers back into dual-redundant (failover) mode by entering the
following command:
$ SET FAILOVER COPY=CONFIGURATION_SOURCE
9.2.2.2
Different Product IDs and Compaq Tru64 UNIX V4.0x
for Dual-Redundant Shutdown Upgrade
1.
Halt all host I/O activity to the controller and prepare the host system for a
controller shutdown using the appropriate procedures for your operating
system.
2.
Establish a local connection to the controller through the maintenance port
of the controller.
3.
Enter the SET NOFAILOVER command to take the controllers out of dual-
redundant (failover) mode.
$ SET NOFAILOVER
4. Shutdown the controller with the following command:
SHUTDOWN THIS_CONTROLLER
CAUTION
Failure to shut down the controller in this step could result in
problems with RAIDsets and cache when the controller is reset.