RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX Release Notes

RAID Array 450 HSZ50 HSOF Software Version 5.7 for Compaq Tru64 UNIX
Page 62 AAR1ZZE
TE
c. At this point, you should reboot the system (ONLY TO SINGLE-USER
MODE).
Then mount the root file system to enable writing to the disk:
# shutdown -h now
.
.
.
P00>>> boot -flag s dkb600
.
.
.
Starting secondary cpu 1
INIT: SINGLE-USER MODE
# mountroot
.
.
.
d. Examine the output of "hwmgr -view devices" and "hwmgr -show scsi"
(The scsi DID output will be necessary to execute the hwmgr redirect
commands).
# hwmgr -view dev -cat disk
HWID: Device Name Mfg Model Location
----------------------------------------------------------
27: /dev/disk/floppy0c 3.5in floppy fdi0-unit-0
34: /dev/disk/dsk0c DEC RZ28 (C) DEC bus-0-targ-1-lun-0
35: /dev/disk/dsk1c DEC RZ26L (C) DEC bus-0-targ-2-lun-0
36:/dev/disk/cdrom0c DEC RRD44 (C) DEC bus-0-targ-5-lun-0
39: /dev/disk/dsk4c DEC HSZ50 (C) DEC bus-1-targ-6-lun-0
40: /dev/disk/dsk5c DEC HSZ50 (C) DEC bus-1-targ-6-lun-1
44: /dev/disk/dsk6c DEC HSZ50 (C) DEC bus-1-targ-3-lun-0
45: /dev/disk/dsk7c DEC HSZ50 (C) DEC bus-1-targ-3-lun-1