4. Electrical Specifications
4.1 Recommended operating conditions
Table 4-1 Recommended operating conditions
Parameter Min Type Max Units
Storage temperature -30 +25 +85 °C
Recommend operating temperature -10 +25 +60 °C
Extend operating temperature -20 +25 +75 °C
Operating voltage 3.135
3.3 3.465 Vdc
Operating T77H468 device under conditions beyond its absolute maximum ratings (Table
4-1) may damage the device. Absolute maximum ratings are limiting values to be
considered individually when all other parameters are within their specified operating ranges.
Functional operation and specification compliance under any absolute maximum condition,
or after exposure to any of these conditions, is not guaranteed or implied. Exposure may
affect device reliability
4.2 Power consumption
Table 4-2 Radio system power consumption
Test condition Estimated power range goal
GSM in standby mode <5mA
GSM (Tx=31dBm) <500mA
WCDMA in standby mode <5mA
WCDMA (Tx=24dBm) <900mA
CDMA in standby mode <5mA
CDMA (Tx=24dBm) <900mA
LTE in standby mode <5mA
LTE (64QAM) Tx=23 dBm <900mA
GPS tracking <200mA
Glonass tracking, high sensitivity <260mA
Remark: Above specification is our target, we are working on current consumption
optimization, we will update after finish current consumption measurement.