Specifications
264 Getting Help
Environment Temperature Range
• Powered on: 32° to 104°F (0° to 40°C)
• Powered off: –14° to 140°F (–10° to 60°C)
• Convection cooling, fanless design
Humidity
• 20 to 80% noncondensing
Operating Altitude Range
• 0 to 10,000 feet (0 to 3,050 meters)
Power • Worldwide auto-sensing 90-264 V ac,
47-63 Hz
• Energy-saving automatic power-down
Regulatory Compliance Ergonomics
• German ZH1/618
• EN29241-3 approved
• EPA Energy Star
Safety
• UL 1950, CSA 950
• TÜV-GS approved
• EN 60950 approved
RF Interference
•FCCClassB
•CEmark
• EN55022B
•VCCI
Footnotes:
1
Monitor or speakers and microphone not included.
2
Firmware to support this feature will be available in a future software release.
3
Keyboard not included with international models.
4
For supported peripherals, refer to http://www.compaq.com.
Table 44-2 Winterm Model T1010 Terminal Specifications, Continued
Description Specification