User's Guide

The OneCommand Manager User Manual Page 59
2. Select a OneConnect four-port adapter ASIC in the discovery-tree.
Figure 29: ASIC Information tab
ASIC Information Field Definitions
Model - The model of the selected adapter.
Serial Number - The serial number of the selected adapter.
Active Firmware Version - The version of the firmware running on the selected adapter.
Firmware State - The condition of the firmware.
BIOS Version - The version of the BIOS in use.
HW Version - The hardware version of the selected adapter.
NCSI Version - The Network Controller Sideband Interface version.
IPL File Name - The name of the IPL (Initial Program Load) file currently loaded.
PCI Express Link Speed - The speed of the PCI bus in which the adapter running.
PCI Express Bus Width - The number of lanes for the slot in which the adapter is running.
Adapter Temperature - If the adapter's temperature is not available, “Not Supported” is
displayed. (Not supported on VMware ESX servers being managed through the CIM interface.)
If supported by the adapter, this field displays the adapter's temperature and one of the following
temperature-related status messages:
Normal: The adapter’s temperature is within normal operational range.
Exceeded operational range - Critical: The adapter’s temperature is beyond normal
operational range. If the temperature continues to increase, the adapter shuts down. You
must determine the cause of the temperature problem and fix it immediately. Check for
system cooling issues. Common causes of system cooling issues include clogged air filters,
inoperable fans and air conditioning problems that cause high ambient air temperatures.
Exceeds operational range: The temperature has reached critical limit. You must determine
the cause of the temperature problem and fix it before resuming operation. Check for system
cooling issues. Common causes of system cooling issues include clogged air filters,
inoperable fans and air conditioning problems that cause high ambient air temperatures.